Air handler ducts in attic vented or unvented compliance must be demonstrated via energy modeling with cbecc res software.
Attic ventilation requirements california.
Chapter 7a says that vents must resist the intrusion of embers and flames or that they shall be protected by corrosion resistant noncombustible wire mesh screen with openings.
1 8 mesh is also allowed.
The bottom of outdoor air intakes shall be located as high as practicable but not less than 10 feet 3048 mm above ground level.
Upper ventilators sha ll be.
In no case should the amount of exhaust ventilation exceed the amount of intake ventilation.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Mandatory minimum r 22 attic insulation unvented attics must be air sealed at roof deck eaves gables and penetrations.
Ventilators located in the upper portion of the.
Gables to be insulated as exterior walls.
So mechanical ventilation is now required in california to improve indoor air quality in all new residential construction when alterations are made to a residence and in residential additions of 1 000 sq ft or greater.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Always have a balanced ventilation system.
Three frieze block vent holes can be seen in one section of blocking.
The uniform building code requires enclosed attic spaces enclosed rafter spaces and under floor areas to be ventilated by not less than 1 square foot for each 150 square feet of attic under floor area.
That is openings doors windows and louvers to the outside should create a natural flow of fresh.
If your attic is enclosed california s building code states it should have cross ventilation.
Area shall be 1 300of the vented space provided.
The required ventilating area is provided by.
The chart below represents the net minimum area in square inches required for proper ventilation.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Attic or rafter space.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
No less than 40 and not more than 50 of.